NOTE
When installing MB Tension Sensors with
asymmetrical wrap, angle A must be on the same
side as the Pivot Point or angle A must be on the
side away from the Pivot Point.
ASYMMETRICAL WRAP (See Figure 12)
When angle A is less than angle B, or angle A is less
than B, the web angle is asymmetrical. The force acting
perpendicular to the top plate can be computed from the
following formulae:
Wrap Angles (Check appropriate boxes.)
Angle a = 90
o
Angle A or A’ =
o
Angle B or B’ =
o
Angle A- B; or A’ - B’ = D
o
o
-
o
= + D
o
NOTE
If D
o
is > 25
o
, consult factory. If D
o
is < 25
o
,
proceed
with force calculation.
For Normal Wrap
Where: F = Resultant Force.
T = Web Tension.
F = (T cos A) + (T cos B)
_______+_______=_______
For Reverse Wrap
Where: F’ = Resultant Force.
T’ = Web Tension.
F’ = (T’ cos A’) + (T’ cos B’)
_______+_______=_______
FIGURE 12
T
F
A
B
T
T'
B'
F'
A'
T'
Normal
Wrap
Reverse
Wrap
Pivot
Point
a
a
D
D
SYMMETRICAL WRAP (See Figure 11)
When angle X = angle Y, or X= Y, the web angle is
symmetrical. The resultant for F or F will act into or away
from the top plate or MB Tension Sensor at 90
o
. In this
condition, F or F can be determined by the formula:
For Normal Wrap
Where: F = Resultant Force.
T = Web Tension.
F = 2T cos X
For Reverse Wrap
Where: F’ = Resultant Force.
T’ = Web Tension.
F’ = 2T’ cos X’
WEB FORCES (continued...)